Blue Giant Equipment Corporation

Amp Draw

Electrical Details

Warning!
All Electrical wiring to be done by authorized personnel.
Follow the Electrical Standards for calculations.

HYDRAULIC DOCK LEVELERS
ALL Blue Giant docks, including XDS, DLB, VS use a 1hp motor for all voltages. 

Voltages:


  • 115V / 1PH - Range:110-130 / 50-60 Hz
  • 230V / 1PH - Range:208-240 / 50-60 Hz
  • 230V / 3PH - Range:208-240 / 50-60 Hz
  • 460V / 3PH - Range:380-480 / 50-60 Hz
  • 575V / 3PH - Range:575-600 / 60 Hz

1.0 HP Motor Current:


  • 16 Amp
  • 8.0 Amp
  • 4.0 Amp
  • 2.0 Amp
  • 1.5 Amp

Class CC or Time-Delay :
Recommended Fuses.

  • 20 Amp
  • 10 Amp
  • 6.0 Amp
  • 4.0 Amp
  • 3.0 Amp

HYDRAULIC VEHICLE RESTRAINTS
The StrongArm™ SVR303 use a 1hp motor for all voltages.
The TL85 & TL85A have a 1/2hp motor for all voltages.

   

Voltages:


  • 115V / 1PH - Range:110-130 / 50-60 Hz
  • 230V / 1PH - Range:208-240 / 50-60 Hz
  • 230V / 3PH - Range:208-240 / 50-60 Hz
  • 460V / 3PH - Range:380-480 / 50-60 Hz
  • 575V / 3PH - Range:575-600 / 60 Hz

1/2 HP Motor Current:


  • 10 Amp
  • 5.0 Amp
  • 2.0 Amp
  • 1.0 Amp
  • 0.75 Amp

Class CC or Time-Delay :
Recommended Fuses.

  • 15 Amp
  • 8.0 Amp
  • 4.0 Amp
  • 2.0 Amp
  • 1.5 Amp


ELEVATING DOCKS & SCISSOR LIFTS
All Blue Giant Dock Lifts (ED, SP, FS, DS) are horsepower specific as per request.




© Copyright 2012 All Rights Reserved, Blue Giant